Show Hamamatsu Avalanche Photo Diode 1209013341 - Archived data from Wed, 10. November 2021 14:36:39 CET
This is all the information about APD 1209013341. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1209013341 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E09 |
Break-through voltage: | 442 V |
Voltage for Gain 100 (T=+25°C): | 413.7 V |
Dark current: | 7.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 338 |
Position in Box: | 30 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 279 |
Position in grid: | 12 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 434.1362855 V T = -25 °C: 377.0416479 V |
Voltage for Gain 150: | T = +20 °C: 436.9713045 V T = -25 °C: 379.2304931 V |
Voltage for Gain 200: | T = +20 °C: 437.744475 V T = -25 °C: 386.4031157 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 12.50648219 V-1 T = -25 °C: 4.524033043 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 23.14641174 V-1 T = -25 °C: 14.95667107 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 28.85596796 V-1 T = -25 °C: 53.69674014 V-1 |
Break-through voltage: | T = +20 °C: 437.216177 V T = -25 °C: 405.1331963 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
07. Feb 2022 16:17:41 CET | jreher | Updated APD characteristics via API. |
10. Nov 2021 14:36:52 CET | oafedulidis | Updated APD location via API. |
10. Nov 2021 14:36:39 CET | oafedulidis | Updated APD batch assignment via API. |
16. Apr 2021 21:59:05 CEST | jreher | Updated APD characteristics via API. |
05. Feb 2021 11:31:37 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:42 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:53:50 CEST | jreher | Updated APD location via API. |
03. Aug 2020 16:57:13 CEST | jreher | Updated APD batch assignment via API. |
27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
29. Sep 2017 12:28:59 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:10 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:39:37 CEST | Tobias | Imported from Hamamatsu datasheet. |