Subdetector specification:  
Serial: 1209013338
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H08
Break-through voltage: 444 V
Voltage for Gain 100 (T=+25°C): 416.4 V
Dark current: 9.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 338
Position in Box: 27
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 279
Position in grid: 9
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 437.573542 V     T = -25 °C: 378.1039285 V
Voltage for Gain 150: T = +20 °C: 438.531067 V     T = -25 °C: 385.5204195 V
Voltage for Gain 200: T = +20 °C: 438.531067 V     T = -25 °C: 388.1894984 V
Gain/Voltage slope at M = 100: T = +20 °C: 11.72786288 V-1     T = -25 °C: 32.37800935 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 13.92464804 V-1     T = -25 °C: 28.84114854 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.92464804 V-1     T = -25 °C: 31.7335991 V-1
Break-through voltage: T = +20 °C: 438.8327945 V     T = -25 °C: 407.32125 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:41 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:36:52 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:36:39 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:59:04 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:36 CET jreher Updated box and position via API.
07. Oct 2020 15:45:42 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:50 CEST jreher Updated APD location via API.
03. Aug 2020 16:57:13 CEST jreher Updated APD batch assignment via API.
27. Oct 2017 10:23:25 CEST Tobias Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated.
29. Sep 2017 12:28:59 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:10 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:37 CEST Tobias Imported from Hamamatsu datasheet.