RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1205013052 - Archived data from Wed, 10. November 2021 14:36:49 CET


This is all the information about APD 1205013052. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1205013052
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 443 V
Voltage for Gain 100 (T=+25°C): 414.3 V
Dark current: 11.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 338
Position in Box: 6
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 266
Position in grid: 6
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 437.879545 V     T = -25 °C: 377.1026203 V
Voltage for Gain 150: T = +20 °C: 437.879545 V     T = -25 °C: 385.1933191 V
Voltage for Gain 200: T = +20 °C: 437.879545 V     T = -25 °C: 389.7014117 V
Gain/Voltage slope at M = 100: T = +20 °C: -97.27131191 V-1     T = -25 °C: 4.441188739 V-1
Gain/Voltage slope at M = 150: T = +20 °C: -97.27131191 V-1     T = -25 °C: 8.533226007 V-1
Gain/Voltage slope at M = 200: T = +20 °C: -97.27131191 V-1     T = -25 °C: 14.61325681 V-1
Break-through voltage: T = +20 °C: 439.9555207 V     T = -25 °C: 406.3695946 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:37 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:36:49 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:36:36 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:59:00 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:34 CET jreher Updated box and position via API.
07. Oct 2020 15:45:40 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:48 CEST jreher Updated APD location via API.
03. Aug 2020 16:52:39 CEST jreher Updated APD batch assignment via API.
01. Aug 2016 17:28:01 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:30 CEST Tobias Imported from Hamamatsu datasheet.