Show Hamamatsu Avalanche Photo Diode 1203012913 - Archived data from Tue, 11. August 2020 17:57:50 CEST
This is all the information about APD 1203012913. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1203012913 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F10 |
Break-through voltage: | 440 V |
Voltage for Gain 100 (T=+25°C): | 411.7 V |
Dark current: | 10.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 304 |
Position in Box: | 19 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 259 |
Position in grid: | 16 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 20. Oct 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 411.7 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 411.89203 V T = -25 °C: 375.1330214 V |
Voltage for Gain 150: | T = +20 °C: 419.9091281 V T = -25 °C: 383.0622804 V |
Voltage for Gain 200: | T = +20 °C: 424.3640707 V T = -25 °C: 387.4717129 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.530583375 V-1 T = -25 °C: 4.493266495 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.88105863 V-1 T = -25 °C: 8.831311809 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.70309955 V-1 T = -25 °C: 15.50839464 V-1 |
Break-through voltage: | T = +20 °C: 439.5663695 V T = -25 °C: 403.0254618 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:31 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:07 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:57:50 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:55 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:46 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:20:00 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:21 CET | jreher | Updated box and position via API. |
20. Oct 2017 14:31:16 CEST | markus.moritz | Entered shipped after irradiation date. |
20. Oct 2017 09:54:14 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 11:51:47 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:27:56 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:37:52 CEST | Tobias | Imported from Hamamatsu datasheet. |