Subdetector specification:  
Serial: 1202012824
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E02
Break-through voltage: 432 V
Voltage for Gain 100 (T=+25°C): 403.5 V
Dark current: 10.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 379
Position in Box: 9
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 255
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 1
Bias voltage: 403.5 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
16. Apr 2021 22:03:04 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:36:56 CET jreher Updated box and position via API.
13. Oct 2020 16:49:48 CEST vwerner Updated APD batch assignment via API.
08. Oct 2020 18:19:48 CEST jreher Updated APD location via API.
23. Nov 2017 11:58:27 CET markus.moritz Entered shipped after irradiation date.
23. Nov 2017 11:54:44 CET markus.moritz Entered irradiation information.
29. Sep 2017 11:45:43 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:27:54 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:37:50 CEST Tobias Imported from Hamamatsu datasheet.