Show Hamamatsu Avalanche Photo Diode 1201012784 - Archived data from Tue, 11. August 2020 17:57:54 CEST
This is all the information about APD 1201012784. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1201012784 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C06 |
Break-through voltage: | 443 V |
Voltage for Gain 100 (T=+25°C): | 414 V |
Dark current: | 7.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 304 |
Position in Box: | 36 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 253 |
Position in grid: | 17 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 27. Oct 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 25. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 1 |
Bias voltage: | 414 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 414.6742716 V T = -25 °C: 377.8345026 V |
Voltage for Gain 150: | T = +20 °C: 422.653474 V T = -25 °C: 385.7234495 V |
Voltage for Gain 200: | T = +20 °C: 427.0664729 V T = -25 °C: 390.0855873 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.296336735 V-1 T = -25 °C: 4.645781357 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.199883268 V-1 T = -25 °C: 9.237126769 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.31662833 V-1 T = -25 °C: 14.46026984 V-1 |
Break-through voltage: | T = +20 °C: 439.9874029 V T = -25 °C: 405.4010162 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:33 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:09 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:57:54 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:56 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:47 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:20:25 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:23 CET | jreher | Updated box and position via API. |
27. Oct 2017 10:38:42 CEST | markus.moritz | Entered shipped after irradiation date. |
26. Oct 2017 16:29:49 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 11:53:38 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:27:52 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:37:49 CEST | Tobias | Imported from Hamamatsu datasheet. |