RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1201012757 - Archived data from Tue, 22. February 2022 10:41:38 CET


This is all the information about APD 1201012757. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1201012757
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D02
Break-through voltage: 447 V
Voltage for Gain 100 (T=+25°C): 418.4 V
Dark current: 8.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 334
Position in Box: 29
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 252
Position in grid: 3
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 438.813451 V     T = -25 °C: 381.0224574 V
Voltage for Gain 150: T = +20 °C: 438.813451 V     T = -25 °C: 389.0305796 V
Voltage for Gain 200: T = +20 °C: 438.813451 V     T = -25 °C: 393.4908277 V
Gain/Voltage slope at M = 100: T = +20 °C: -28.92173313 V-1     T = -25 °C: 4.496837136 V-1
Gain/Voltage slope at M = 150: T = +20 °C: -28.92173313 V-1     T = -25 °C: 8.82354308 V-1
Gain/Voltage slope at M = 200: T = +20 °C: -28.92173313 V-1     T = -25 °C: 15.25875989 V-1
Break-through voltage: T = +20 °C: 439.9685515 V     T = -25 °C: 409.757067 V
   
Notes:


Version history

Time Author Change comment
28. Jul 2022 13:18:00 CEST oafedulidis Updated box and position via API.
28. Jul 2022 13:15:16 CEST oafedulidis Updated APD location via API.
08. Mar 2022 14:29:12 CET oafedulidis Updated APD characteristics via API.
08. Mar 2022 13:53:56 CET oafedulidis Updated APD batch assignment via API.
22. Feb 2022 10:41:58 CET oafedulidis Updated APD location via API.
22. Feb 2022 10:41:38 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:28 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:06 CET jreher Updated box and position via API.
07. Oct 2020 15:45:28 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:33 CEST jreher Updated APD location via API.
21. Jul 2020 16:25:52 CEST jreher Updated APD batch assignment via API.
01. Aug 2016 17:27:51 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:37:48 CEST Tobias Imported from Hamamatsu datasheet.