RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1201012754 - Archived data from Tue, 08. March 2022 14:29:11 CET


This is all the information about APD 1201012754. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1201012754
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 445 V
Voltage for Gain 100 (T=+25°C): 417.5 V
Dark current: 7.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 334
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 252
Position in grid: 16
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 418.0727991 V     T = -25 °C: 381.0090928 V
Voltage for Gain 150: T = +20 °C: 425.963809 V     T = -25 °C: 388.9010467 V
Voltage for Gain 200: T = +20 °C: 430.3487398 V     T = -25 °C: 393.2917406 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.53496303 V-1     T = -25 °C: 4.569652523 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.981064667 V-1     T = -25 °C: 8.998690587 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.94683065 V-1     T = -25 °C: 13.98729718 V-1
Break-through voltage: T = +20 °C: 444.9726083 V     T = -25 °C: 408.7356542 V
   
Notes:


Version history

Time Author Change comment
28. Jul 2022 13:17:59 CEST oafedulidis Updated box and position via API.
28. Jul 2022 13:15:16 CEST oafedulidis Updated APD location via API.
08. Mar 2022 14:29:11 CET oafedulidis Updated APD characteristics via API.
08. Mar 2022 13:53:56 CET oafedulidis Updated APD batch assignment via API.
22. Feb 2022 10:41:57 CET oafedulidis Updated APD location via API.
22. Feb 2022 10:41:37 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:28 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:06 CET jreher Updated box and position via API.
07. Oct 2020 15:45:27 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:32 CEST jreher Updated APD location via API.
21. Jul 2020 16:25:51 CEST jreher Updated APD batch assignment via API.
01. Aug 2016 17:27:51 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:37:48 CEST Tobias Imported from Hamamatsu datasheet.