RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1201012750 - Archived data from Fri, 16. April 2021 21:58:27 CEST


This is all the information about APD 1201012750. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1201012750
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 443 V
Voltage for Gain 100 (T=+25°C): 414.3 V
Dark current: 27.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 334
Position in Box: 23
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 252
Position in grid: 10
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 437.833845 V     T = -25 °C: 377.2204458 V
Voltage for Gain 150: T = +20 °C: 437.833845 V     T = -25 °C: 385.1343974 V
Voltage for Gain 200: T = +20 °C: 437.833845 V     T = -25 °C: 389.5240194 V
Gain/Voltage slope at M = 100: T = +20 °C: -132.1547492 V-1     T = -25 °C: 4.499401836 V-1
Gain/Voltage slope at M = 150: T = +20 °C: -132.1547492 V-1     T = -25 °C: 8.767809753 V-1
Gain/Voltage slope at M = 200: T = +20 °C: -132.1547492 V-1     T = -25 °C: 15.26404202 V-1
Break-through voltage: T = +20 °C: 439.9179476 V     T = -25 °C: 404.9519567 V
   
Notes:


Version history

Time Author Change comment
28. Jul 2022 13:17:58 CEST oafedulidis Updated box and position via API.
28. Jul 2022 13:15:16 CEST oafedulidis Updated APD location via API.
08. Mar 2022 14:29:11 CET oafedulidis Updated APD characteristics via API.
08. Mar 2022 13:53:55 CET oafedulidis Updated APD batch assignment via API.
22. Feb 2022 10:41:57 CET oafedulidis Updated APD location via API.
22. Feb 2022 10:41:37 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:27 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:05 CET jreher Updated box and position via API.
07. Oct 2020 15:45:27 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:32 CEST jreher Updated APD location via API.
21. Jul 2020 16:25:51 CEST jreher Updated APD batch assignment via API.
01. Aug 2016 17:27:51 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:37:47 CEST Tobias Imported from Hamamatsu datasheet.