RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1201012743 - Archived data from Tue, 20. July 2021 14:53:56 CEST


This is all the information about APD 1201012743. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1201012743
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Waiting for Irraddiation in Giessen
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B09
Break-through voltage: 447 V
Voltage for Gain 100 (T=+25°C): 418.1 V
Dark current: 7.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 518
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 251
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
15. Nov 2021 16:06:33 CET oafedulidis Updated APD batch assignment via API.
27. Jul 2021 16:23:11 CEST oafedulidis Updated box and position via API.
20. Jul 2021 14:54:13 CEST oafedulidis Updated APD location via API.
20. Jul 2021 14:53:56 CEST oafedulidis Updated box and position via API.
19. May 2021 14:43:03 CEST jreher Updated APD location via API.
29. Sep 2017 09:58:30 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:27:51 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:37:47 CEST Tobias Imported from Hamamatsu datasheet.