Show Hamamatsu Avalanche Photo Diode 0918010313 - Archived data from Wed, 07. October 2020 15:45:34 CEST
This is all the information about APD 0918010313. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0918010313 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C05 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 382.6 V |
Dark current: | 3.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 336 |
Position in Box: | 2 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 412.60735 V T = -25 °C: 347.1251972 V |
Voltage for Gain 150: | T = +20 °C: 412.60735 V T = -25 °C: 354.5636721 V |
Voltage for Gain 200: | T = +20 °C: 412.60735 V T = -25 °C: 358.7268386 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 925.6902392 V-1 T = -25 °C: 4.872492227 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 925.6902392 V-1 T = -25 °C: 8.929024206 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 925.6902392 V-1 T = -25 °C: 15.74400114 V-1 |
Break-through voltage: | T = +20 °C: 410.9769393 V T = -25 °C: 373.8785366 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
07. Feb 2022 16:17:27 CET | jreher | Updated APD characteristics via API. |
10. Nov 2021 14:35:51 CET | oafedulidis | Updated APD location via API. |
10. Nov 2021 14:35:36 CET | oafedulidis | Updated APD batch assignment via API. |
05. Feb 2021 11:31:18 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:34 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:10:44 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:53:39 CEST | jreher | Updated APD location via API. |
21. Jul 2020 16:16:40 CEST | jreher | Updated APD batch assignment via API. |
22. Jun 2016 15:36:13 CEST | Tobias | Imported from Hamamatsu datasheet. |