RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0917010250 - Archived data from Fri, 16. April 2021 21:59:21 CEST


This is all the information about APD 0917010250. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0917010250
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C15
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 382.8 V
Dark current: 3.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 340
Position in Box: 14
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.5687134 V     T = -25 °C: 346.895077 V
Voltage for Gain 150: T = +20 °C: 390.471133 V     T = -25 °C: 354.2924016 V
Voltage for Gain 200: T = +20 °C: 394.850675 V     T = -25 °C: 358.4521139 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.37979346 V-1     T = -25 °C: 4.965107064 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.497617228 V-1     T = -25 °C: 9.214445474 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.69908648 V-1     T = -25 °C: 16.25614194 V-1
Break-through voltage: T = +20 °C: 405.0664119 V     T = -25 °C: 373.077477 V
   
Notes:


Version history

Time Author Change comment
25. Sep 2021 16:12:40 CEST oafedulidis Assigned to capsule by script
16. Apr 2021 21:59:21 CEST jreher Updated APD characteristics via API.
15. Apr 2021 17:00:45 CEST jreher Updated box and position via API.
05. Feb 2021 11:31:51 CET jreher Updated box and position via API.
17. Aug 2020 14:50:00 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:53:58 CEST jreher Updated APD location via API.
22. Jun 2016 15:36:12 CEST Tobias Imported from Hamamatsu datasheet.