Show Hamamatsu Avalanche Photo Diode 0911009805 - Archived data from Wed, 22. June 2016 15:34:22 CEST


This is all the information about APD 0911009805. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0911009805
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D03
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.4 V
Dark current: 3.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 292
Position in Box: 45
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:26:01 CET jreher Updated box and position via API.
07. Oct 2020 15:45:00 CEST jreher Updated APD location via API.
11. Aug 2020 17:40:46 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:03 CEST jreher Updated box and position via API.
27. Nov 2019 20:19:14 CET jreher Updated APD location via API.
25. Nov 2019 17:31:39 CET jreher Updated box and position via API.
22. Oct 2019 14:33:22 CEST spankonin Updated APD location via API.
15. Oct 2019 10:59:39 CEST jgrochowski Updated APD batch assignment via API.
04. Aug 2016 13:25:45 CEST markus.moritz Entered return for assembly date.
03. Aug 2016 16:12:47 CEST markus.moritz Entered shipped after irradiation date.
03. Aug 2016 16:12:38 CEST markus.moritz Entered arrival for irradiation date.
02. Aug 2016 16:28:36 CEST markus.moritz Entered irradiation information.
02. Aug 2016 15:21:42 CEST christopher.l.hahn Entered annealing information.
01. Aug 2016 17:27:39 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:34:22 CEST Tobias Imported from Hamamatsu datasheet.