Show Hamamatsu Avalanche Photo Diode 0911009756 - Archived data from Thu, 04. July 2019 11:11:38 CEST
This is all the information about APD 0911009756. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0911009756 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 44 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | H07 |
Break-through voltage: | 407 V |
Voltage for Gain 100 (T=+25°C): | 378.7 V |
Dark current: | 4.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 44 |
Position in Box: | 46 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 208 |
Position in grid: | 1 |
Arrival for irradiation: | 12. Jul 2016 |
Sent for analysis after irradiation: | 22. Jul 2016 |
Return for assembly: | 19. Sep 2016 |
Irradiation: | |
Date: | 12. Jul 2016 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 4 |
Bias voltage: | 320 V (connection unknown) |
Annealing: | |
Date: | 12. Jul 2016 |
Temperature: | 80 °C |
Duration: | 10 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2022 10:00:58 CET | oafedulidis | Assigned to capsule by script |
16. Dec 2021 13:42:03 CET | oafedulidis | Updated box and position via API. |
22. Feb 2021 11:10:51 CET | jreher | Updated box and position via API. |
05. Feb 2021 10:53:54 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:41 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:55 CEST | jreher | Updated APD characteristics via API. |
04. Aug 2020 15:48:20 CEST | jreher | Updated box and position via API. |
27. Nov 2019 19:36:50 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:27 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:38 CEST | jreher | Updated APD location via API. |
13. Jun 2019 10:01:31 CEST | jreher | Updated APD batch assignment via API. |
23. Sep 2016 09:06:00 CEST | markus.moritz | Entered return for assembly date. |
03. Aug 2016 16:11:23 CEST | markus.moritz | Entered shipped after irradiation date. |
03. Aug 2016 16:10:59 CEST | markus.moritz | Entered arrival for irradiation date. |
02. Aug 2016 16:27:25 CEST | markus.moritz | Entered irradiation information. |
02. Aug 2016 14:57:48 CEST | christopher.l.hahn | Entered annealing information. |
01. Aug 2016 17:27:44 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:34:20 CEST | Tobias | Imported from Hamamatsu datasheet. |