RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0910009745 - Archived data from Wed, 03. August 2016 16:10:27 CEST


This is all the information about APD 0910009745. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0910009745
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.4 V
Dark current: 3.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 44
Position in Box: 45
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 207
Position in grid: 19
Arrival for irradiation: 15. May 2016
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: 20. May 2016
Dose used: 57 Gy
Temperature: -25 °C
Position: 1
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 20. May 2016
Temperature: 80 °C
Duration: 8 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
22. Feb 2021 11:10:51 CET jreher Updated box and position via API.
05. Feb 2021 10:53:54 CET jreher Updated box and position via API.
03. Feb 2021 18:19:41 CET jreher Updated box and position via API.
11. Aug 2020 17:26:55 CEST jreher Updated APD characteristics via API.
04. Aug 2020 15:48:20 CEST jreher Updated box and position via API.
27. Nov 2019 19:36:50 CET jreher Updated APD location via API.
25. Nov 2019 17:14:27 CET jreher Updated box and position via API.
04. Jul 2019 11:11:38 CEST jreher Updated APD location via API.
13. Jun 2019 10:01:31 CEST jreher Updated APD batch assignment via API.
20. Dec 2016 10:37:11 CET markus.moritz Entered return for assembly date.
03. Aug 2016 16:10:39 CEST markus.moritz Entered shipped after irradiation date.
03. Aug 2016 16:10:27 CEST markus.moritz Entered arrival for irradiation date.
03. Aug 2016 10:52:06 CEST tobias Repaired loop-off-by-1 error in save script.
03. Aug 2016 10:36:45 CEST tobias Repaired loop-off-by-1 error in save script.
01. Aug 2016 17:52:07 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:34:20 CEST Tobias Imported from Hamamatsu datasheet.