Show Hamamatsu Avalanche Photo Diode 0910009741
This is all the information about APD 0910009741. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0910009741 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 0804007461/0910009741 |
Unit: | #863 (barcode 1309009466) |
Preamp: | 4356 |
Current location: | Bochum |
Installation information: | |
Label: | red |
Manufacturer information: | |
Wafer position: | E04 |
Break-through voltage: | 416 V |
Voltage for Gain 100 (T=+25°C): | 387.9 V |
Dark current: | 3 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 44 |
Position in Box: | 36 |
EP1 batch: | none |
EP1 batch after irradiation: | 10072 |
Shipment: | |
Grid number: | 207 |
Position in grid: | 11 |
Arrival for irradiation: | 15. May 2016 |
Sent for analysis after irradiation: | 23. Jun 2016 |
Return for assembly: | 20. Dec 2016 |
Irradiation: | |
Date: | 20. May 2016 |
Dose used: | 57 Gy |
Temperature: | -25 °C |
Position: | 1 |
Bias voltage: | 320 V (connection unknown) |
Annealing: | |
Date: | 20. May 2016 |
Temperature: | 80 °C |
Duration: | 8 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 387.9434618 V T = -25 °C: 351.7551583 V |
Voltage for Gain 150: | T = +20 °C: 395.9047086 V T = -25 °C: 359.3308972 V |
Voltage for Gain 200: | T = +20 °C: 400.3158727 V T = -25 °C: 363.60895 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.438569414 V-1 T = -25 °C: 4.784435905 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.485581564 V-1 T = -25 °C: 9.347894645 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.31434816 V-1 T = -25 °C: 14.20794374 V-1 |
Break-through voltage: | T = +20 °C: 415.7696961 V T = -25 °C: 378.905238 V |
Notes: | has been irradiated and annealed again (sent to Gießen on 24_07_2018, irradiated on 16_08_2018 with 30Gy at 20°C, annealed on 17_08_2018 at 80°C for 48h, sent to analysis on 21_08_2018) |
Characteristics
Temperature | Measurement | Notes |
---|---|---|
No characteristics available! |
Progression of the current during irradiation
Upload time | Notes |
---|---|
No data available! |
Upload new progression data...
Version history
Time | Author | Change comment |
---|---|---|
22. Feb 2021 11:10:50 CET | jreher | Updated box and position via API. |
05. Feb 2021 10:53:52 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:40 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:54 CEST | jreher | Updated APD characteristics via API. |
04. Aug 2020 15:48:19 CEST | jreher | Updated box and position via API. |
13. Feb 2020 14:42:52 CET | jreher | Updated box and position via API. |
27. Nov 2019 19:36:50 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:26 CET | jreher | Updated box and position via API. |
17. Oct 2019 14:09:41 CEST | tholtmann | Assigned to unit by script |
17. Oct 2019 13:54:16 CEST | tholtmann | Assigned to capsule by script |
04. Jul 2019 11:11:36 CEST | jreher | Updated APD location via API. |
13. Jun 2019 10:01:13 CEST | jreher | Updated APD batch assignment via API. |
21. Aug 2018 11:46:16 CEST | markus.moritz | |
20. Dec 2016 10:37:11 CET | markus.moritz | Entered return for assembly date. |
03. Aug 2016 16:10:39 CEST | markus.moritz | Entered shipped after irradiation date. |
03. Aug 2016 16:10:26 CEST | markus.moritz | Entered arrival for irradiation date. |
02. Aug 2016 16:26:46 CEST | markus.moritz | Entered irradiation information. |
02. Aug 2016 15:17:47 CEST | christopher.l.hahn | Entered annealing information. |
01. Aug 2016 17:52:07 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:34:20 CEST | Tobias | Imported from Hamamatsu datasheet. |