Show Hamamatsu Avalanche Photo Diode 0910009731
This is all the information about APD 0910009731. If it is wrong, edit the data.
Subdetector specification: |
|
Serial: |
0910009731 |
Type: |
Hamamatsu Avalanche Photo Diode |
Detector: |
unassigned |
Unit: |
unassigned |
Preamp: |
0 |
Current location: |
Bochum |
|
|
Installation information: |
|
Label: |
none |
|
|
Manufacturer information: |
|
Wafer position: |
F05 |
Break-through voltage: |
415 V |
Voltage for Gain 100 (T=+25°C): |
387.9 V |
Dark current: |
3.2 nA |
|
|
Screening Logistics: |
|
Available: |
Yes |
Storage Box: |
44 |
Position in Box: |
34 |
EP1 batch: |
none |
EP1 batch after irradiation: |
10072 |
|
|
Shipment: |
|
Grid number: |
207 |
Position in grid: |
10 |
Arrival for irradiation: |
15. May 2016 |
Sent for analysis after irradiation: |
23. Jun 2016 |
Return for assembly: |
20. Dec 2016 |
|
|
Irradiation: |
|
Date: |
20. May 2016 |
Dose used: |
57 Gy |
Temperature: |
-25 °C |
Position: |
1 |
Bias voltage: |
320 V (connection unknown) |
|
|
Annealing: |
|
Date: |
20. May 2016 |
Temperature: |
80 °C |
Duration: |
8 h |
|
|
Measurement results: |
|
Voltage for Gain 100: |
T = +20 °C: 387.625657 V T = -25 °C: 351.4228287 V |
Voltage for Gain 150: |
T = +20 °C: 395.5717796 V T = -25 °C: 358.9964796 V |
Voltage for Gain 200: |
T = +20 °C: 399.9889656 V T = -25 °C: 363.2536537 V |
Gain/Voltage slope at M = 100: |
T = +20 °C: 4.532262948 V-1 T = -25 °C: 4.908534441 V-1 |
Gain/Voltage slope at M = 150: |
T = +20 °C: 8.735301651 V-1 T = -25 °C: 9.615226496 V-1 |
Gain/Voltage slope at M = 200: |
T = +20 °C: 14.83967177 V-1 T = -25 °C: 14.71436925 V-1 |
Break-through voltage: |
T = +20 °C: 414.906597 V T = -25 °C: 378.0369303 V |
|
|
Notes: |
has been irradiated and annealed again (sent to Gießen on 24_07_2018, irradiated on 16_08_2018 with 30Gy at 20°C, annealed on 17_08_2018 at 80°C for 48h, sent to analysis on 21_08_2018)
|
Characteristics
Temperature |
Measurement |
Notes |
No characteristics available! |
Upload new characteristic...
Progression of the current during irradiation
Upload time |
Notes |
No data available! |
Upload new progression data...
Version history