Show Hamamatsu Avalanche Photo Diode 0910009725 - Archived data from Mon, 01. August 2016 17:52:06 CEST
This is all the information about APD 0910009725. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0910009725 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D11 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 389.8 V |
Dark current: | 5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 289 |
Position in Box: | 18 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 207 |
Position in grid: | 2 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:34 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:48 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:40:11 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:31 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:38 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:23 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:31:14 CEST | spankonin | Updated APD location via API. |
14. Oct 2019 17:33:21 CEST | jgrochowski | Updated APD batch assignment via API. |
20. Dec 2016 10:37:11 CET | markus.moritz | Entered return for assembly date. |
03. Aug 2016 16:10:39 CEST | markus.moritz | Entered shipped after irradiation date. |
03. Aug 2016 16:10:26 CEST | markus.moritz | Entered arrival for irradiation date. |
02. Aug 2016 16:26:46 CEST | markus.moritz | Entered irradiation information. |
02. Aug 2016 15:17:47 CEST | christopher.l.hahn | Entered annealing information. |
01. Aug 2016 17:52:06 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:34:20 CEST | Tobias | Imported from Hamamatsu datasheet. |