Show Hamamatsu Avalanche Photo Diode 0909009651 - Archived data from Wed, 07. October 2020 15:45:10 CEST
This is all the information about APD 0909009651. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0909009651 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D03 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 385.7 V |
Dark current: | 3.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 304 |
Position in Box: | 49 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 203 |
Position in grid: | 11 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | 17. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 385.7 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 385.5739173 V T = -25 °C: 349.6950729 V |
Voltage for Gain 150: | T = +20 °C: 393.6065989 V T = -25 °C: 357.2260828 V |
Voltage for Gain 200: | T = +20 °C: 398.0608853 V T = -25 °C: 361.4889658 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.34160361 V-1 T = -25 °C: 4.599799641 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.163353629 V-1 T = -25 °C: 9.105459775 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.21909399 V-1 T = -25 °C: 15.90838205 V-1 |
Break-through voltage: | T = +20 °C: 414.2804073 V T = -25 °C: 377.6118518 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:35 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:10 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:57:57 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:58 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:48 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:20:26 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:24 CET | jreher | Updated box and position via API. |
17. Nov 2017 09:39:37 CET | markus.moritz | Entered shipped after irradiation date. |
17. Nov 2017 09:38:24 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:11:26 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:55 CET | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:34:18 CEST | Tobias | Imported from Hamamatsu datasheet. |