Show Hamamatsu Avalanche Photo Diode 0908009538 - Archived data from Tue, 11. August 2020 17:58:03 CEST
This is all the information about APD 0908009538. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0908009538 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A07 |
Break-through voltage: | 411 V |
Voltage for Gain 100 (T=+25°C): | 382.3 V |
Dark current: | 3.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 305 |
Position in Box: | 31 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 199 |
Position in grid: | 8 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | 17. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 382.3 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 382.4998113 V T = -25 °C: 346.8506728 V |
Voltage for Gain 150: | T = +20 °C: 390.5231321 V T = -25 °C: 354.4021631 V |
Voltage for Gain 200: | T = +20 °C: 394.9824469 V T = -25 °C: 358.6444094 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.345998513 V-1 T = -25 °C: 4.871113112 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.154028674 V-1 T = -25 °C: 8.839870391 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.09162939 V-1 T = -25 °C: 15.39279174 V-1 |
Break-through voltage: | T = +20 °C: 406.6070697 V T = -25 °C: 374.4061688 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:40 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:03 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:44:11 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:44:02 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:33:22 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:30 CET | jreher | Updated box and position via API. |
17. Nov 2017 09:39:30 CET | markus.moritz | Entered shipped after irradiation date. |
17. Nov 2017 09:37:37 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:11:19 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:54 CET | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:34:16 CEST | Tobias | Imported from Hamamatsu datasheet. |