RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0905009315 - Archived data from Fri, 16. April 2021 22:00:52 CEST


This is all the information about APD 0905009315. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0905009315
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.9 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 355
Position in Box: 6
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.5632278 V     T = -25 °C: 344.1918822 V
Voltage for Gain 150: T = +20 °C: 387.4187075 V     T = -25 °C: 351.5068023 V
Voltage for Gain 200: T = +20 °C: 391.7744441 V     T = -25 °C: 355.6193149 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.426506952 V-1     T = -25 °C: 4.900180745 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.60835715 V-1     T = -25 °C: 9.123865811 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.0332565 V-1     T = -25 °C: 16.13842654 V-1
Break-through voltage: T = +20 °C: 407.0507711 V     T = -25 °C: 370.7067034 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 14:46:42 CEST oafedulidis Updated box and position via API.
16. Apr 2021 22:00:52 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:33:48 CET jreher Updated box and position via API.
08. Oct 2020 18:15:10 CEST jreher Updated APD location via API.
17. Aug 2020 14:25:44 CEST vwerner Updated APD batch assignment via API.
22. Jun 2016 15:31:45 CEST Tobias Imported from Hamamatsu datasheet.