Show Hamamatsu Avalanche Photo Diode 0904009312 - Archived data from Wed, 21. April 2021 11:02:46 CEST
This is all the information about APD 0904009312. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0904009312 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | H08 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 385.5 V |
Dark current: | 5.1 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 355 |
Position in Box: | 6 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 386.284122 V T = -25 °C: 350.5165718 V |
Voltage for Gain 150: | T = +20 °C: 394.1586642 V T = -25 °C: 357.9766091 V |
Voltage for Gain 200: | T = +20 °C: 398.6326301 V T = -25 °C: 362.17658 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.482707328 V-1 T = -25 °C: 4.72009423 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.810056416 V-1 T = -25 °C: 9.372723813 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.03594663 V-1 T = -25 °C: 14.70239189 V-1 |
Break-through voltage: | T = +20 °C: 402.857191 V T = -25 °C: 377.1968674 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
26. Oct 2021 16:11:50 CEST | oafedulidis | Assigned to capsule by script |
21. Apr 2021 11:02:46 CEST | jreher | Updated box and position via API. |
16. Apr 2021 22:00:52 CEST | jreher | Updated APD characteristics via API. |
05. Feb 2021 11:33:48 CET | jreher | Updated box and position via API. |
08. Oct 2020 18:15:10 CEST | jreher | Updated APD location via API. |
17. Aug 2020 14:25:44 CEST | vwerner | Updated APD batch assignment via API. |
22. Jun 2016 15:31:45 CEST | Tobias | Imported from Hamamatsu datasheet. |