Show Hamamatsu Avalanche Photo Diode 0904009248 - Archived data from Fri, 17. November 2017 09:37:18 CET
This is all the information about APD 0904009248. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0904009248 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E12 |
Break-through voltage: | 415 V |
Voltage for Gain 100 (T=+25°C): | 386.4 V |
Dark current: | 6.1 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 294 |
Position in Box: | 41 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 186 |
Position in grid: | 18 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 1 |
Bias voltage: | 386.4 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2021 10:34:30 CET | oafedulidis | Assigned to capsule by script |
16. Jun 2021 16:03:29 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:59:47 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:52:27 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:26:15 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:15 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:29 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:41:20 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:44:45 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:06 CET | jreher | Updated box and position via API. |
17. Nov 2017 09:39:23 CET | markus.moritz | Entered shipped after irradiation date. |
17. Nov 2017 09:37:18 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:11:11 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:54 CET | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:31:43 CEST | Tobias | Imported from Hamamatsu datasheet. |