RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0904009245 - Archived data from Wed, 16. June 2021 16:00:26 CEST


This is all the information about APD 0904009245. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0904009245
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G11
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.5 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 294
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 186
Position in grid: 12
Arrival for irradiation: 30. Oct 2017
Sent for analysis after irradiation: 17. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 16. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 1
Bias voltage: 388.5 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.3072463 V     T = -25 °C: 352.305095 V
Voltage for Gain 150: T = +20 °C: 396.2803792 V     T = -25 °C: 359.952613 V
Voltage for Gain 200: T = +20 °C: 400.7113764 V     T = -25 °C: 364.1928646 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.422242965 V-1     T = -25 °C: 4.855229632 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.573993326 V-1     T = -25 °C: 9.954783487 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.85281928 V-1     T = -25 °C: 14.95885054 V-1
Break-through voltage: T = +20 °C: 413.5739593 V     T = -25 °C: 379.9382695 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 16:15:18 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:13 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:26 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:06 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:26:14 CET jreher Updated box and position via API.
11. Aug 2020 17:56:14 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:29 CEST jreher Updated APD location via API.
21. Jul 2020 14:41:19 CEST jreher Updated box and position via API.
19. Dec 2019 15:44:45 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:17:06 CET jreher Updated box and position via API.
17. Nov 2017 09:39:23 CET markus.moritz Entered shipped after irradiation date.
17. Nov 2017 09:37:17 CET markus.moritz Entered irradiation information.
09. Nov 2017 15:11:11 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:54 CET Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:31:43 CEST Tobias Imported from Hamamatsu datasheet.