RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0904009237 - Archived data from Tue, 11. August 2020 17:56:13 CEST


This is all the information about APD 0904009237. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0904009237
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F13
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.5 V
Dark current: 6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 294
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 186
Position in grid: 19
Arrival for irradiation: 30. Oct 2017
Sent for analysis after irradiation: 17. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 16. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 1
Bias voltage: 388.5 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.6467788 V     T = -25 °C: 352.7497136 V
Voltage for Gain 150: T = +20 °C: 396.5287398 V     T = -25 °C: 360.2398231 V
Voltage for Gain 200: T = +20 °C: 400.9926684 V     T = -25 °C: 364.6681228 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.501817515 V-1     T = -25 °C: 4.45908676 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.403233228 V-1     T = -25 °C: 10.05129347 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.04840116 V-1     T = -25 °C: 17.52042836 V-1
Break-through voltage: T = +20 °C: 416.7280615 V     T = -25 °C: 380.0200313 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:26:14 CET jreher Updated box and position via API.
11. Aug 2020 17:56:13 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:29 CEST jreher Updated APD location via API.
21. Jul 2020 14:41:19 CEST jreher Updated box and position via API.
19. Dec 2019 15:44:45 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:17:05 CET jreher Updated box and position via API.
17. Nov 2017 09:39:23 CET markus.moritz Entered shipped after irradiation date.
17. Nov 2017 09:37:18 CET markus.moritz Entered irradiation information.
09. Nov 2017 15:11:11 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:54 CET Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:31:43 CEST Tobias Imported from Hamamatsu datasheet.