RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0902009234 - Archived data from Thu, 02. November 2017 15:16:54 CET


This is all the information about APD 0902009234. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0902009234
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E03
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 373.9 V
Dark current: 9.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 365
Position in Box: 8
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 186
Position in grid: 13
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes: Wrong wafer number in serial number, correct wafer number is 3.


Version history

Time Author Change comment
16. Apr 2021 22:01:47 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:35:06 CET jreher Updated box and position via API.
08. Oct 2020 18:17:05 CEST jreher Updated APD location via API.
28. Sep 2020 15:56:36 CEST vwerner Updated APD batch assignment via API.
09. Nov 2017 16:47:11 CET Tobias Removed APD from grid as the grid arrived in Gießen without it.
09. Nov 2017 15:11:11 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:54 CET Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:03:47 CEST Tobias Added note about wrong wafer number.
22. Jun 2016 15:31:43 CEST Tobias Imported from Hamamatsu datasheet.