Show Hamamatsu Avalanche Photo Diode 0902009203 - Archived data from Fri, 16. April 2021 22:00:54 CEST
This is all the information about APD 0902009203. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0902009203 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | H09 |
Break-through voltage: | 408 V |
Voltage for Gain 100 (T=+25°C): | 379.1 V |
Dark current: | 6.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 355 |
Position in Box: | 22 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 379.6448876 V T = -25 °C: 344.4796927 V |
Voltage for Gain 150: | T = +20 °C: 387.541026 V T = -25 °C: 351.8051167 V |
Voltage for Gain 200: | T = +20 °C: 391.9206203 V T = -25 °C: 355.9350235 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.405941216 V-1 T = -25 °C: 4.791719462 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.480136996 V-1 T = -25 °C: 9.765873693 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.65979936 V-1 T = -25 °C: 15.42433587 V-1 |
Break-through voltage: | T = +20 °C: 407.3575012 V T = -25 °C: 371.2115276 V |
Notes: | Wrong wafer number in serial number, correct wafer number is 3. |
Version history
Time | Author | Change comment |
---|---|---|
17. Jun 2021 18:56:34 CEST | oafedulidis | Assigned to capsule by script |
16. Apr 2021 22:00:54 CEST | jreher | Updated APD characteristics via API. |
16. Feb 2021 12:27:11 CET | jreher | Updated box and position via API. |
05. Feb 2021 11:33:50 CET | jreher | Updated box and position via API. |
08. Oct 2020 18:15:12 CEST | jreher | Updated APD location via API. |
17. Aug 2020 14:25:46 CEST | vwerner | Updated APD batch assignment via API. |
23. Jun 2016 10:03:47 CEST | Tobias | Added note about wrong wafer number. |
22. Jun 2016 15:31:42 CEST | Tobias | Imported from Hamamatsu datasheet. |