Show Hamamatsu Avalanche Photo Diode 0902009194 - Archived data from Wed, 22. June 2016 15:31:42 CEST
This is all the information about APD 0902009194. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0902009194 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B10 |
Break-through voltage: | 406 V |
Voltage for Gain 100 (T=+25°C): | 377.2 V |
Dark current: | 5.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 56 |
Position in Box: | 7 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:55:33 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:21:07 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:28:06 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:38:36 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:15:18 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:12:50 CEST | jreher | Updated APD location via API. |
24. Jun 2019 13:00:46 CEST | jgrochowski | Updated APD batch assignment via API. |
18. Jun 2019 14:02:25 CEST | jgrochowski | Updated APD batch assignment via API. |
04. Jun 2019 11:47:25 CEST | markus.moritz | |
23. Jun 2016 10:03:46 CEST | Tobias | Added note about wrong wafer number. |
22. Jun 2016 15:31:42 CEST | Tobias | Imported from Hamamatsu datasheet. |