RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0902009184 - Archived data from Wed, 03. February 2021 18:21:04 CET


This is all the information about APD 0902009184. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0902009184
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0902009184/0720006897
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.1 V
Dark current: 6 nA
   
Screening Logistics:  
Available: No
Storage Box: 55
Position in Box: 47
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.023389 V     T = -25 °C: 342.6243624 V
Voltage for Gain 150: T = +20 °C: 385.8377427 V     T = -25 °C: 349.8749816 V
Voltage for Gain 200: T = +20 °C: 390.1888448 V     T = -25 °C: 353.9518604 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.62549128 V-1     T = -25 °C: 4.852782339 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.527895827 V-1     T = -25 °C: 9.651647604 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.79871465 V-1     T = -25 °C: 15.89067454 V-1
Break-through voltage: T = +20 °C: 405.5089265 V     T = -25 °C: 369.0562258 V
   
Notes: Wrong wafer number in serial number, correct wafer number is 3.


Version history

Time Author Change comment
05. Feb 2021 10:55:30 CET jreher Updated box and position via API.
03. Feb 2021 18:21:04 CET jreher Updated box and position via API.
11. Aug 2020 17:28:04 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:46:52 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:49 CET jreher Updated box and position via API.
27. Nov 2019 19:38:28 CET jreher Updated APD location via API.
25. Nov 2019 17:15:17 CET jreher Updated box and position via API.
04. Jul 2019 11:12:45 CEST jreher Updated APD location via API.
24. Jun 2019 13:00:45 CEST jgrochowski Updated APD batch assignment via API.
18. Jun 2019 14:02:24 CEST jgrochowski Updated APD batch assignment via API.
04. Jun 2019 11:22:37 CEST markus.moritz
23. Jun 2016 10:03:46 CEST Tobias Added note about wrong wafer number.
22. Jun 2016 15:31:42 CEST Tobias Imported from Hamamatsu datasheet.