RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0902009179 - Archived data from Wed, 21. April 2021 11:02:58 CEST


This is all the information about APD 0902009179. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0902009179
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D12
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.8 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 295
Position in Box: 5
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 183
Position in grid: 18
Arrival for irradiation: 30. Oct 2017
Sent for analysis after irradiation: 17. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 16. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 1
Bias voltage: 378.8 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.9984797 V     T = -25 °C: 343.6983475 V
Voltage for Gain 150: T = +20 °C: 386.9208224 V     T = -25 °C: 351.0374508 V
Voltage for Gain 200: T = +20 °C: 391.3356834 V     T = -25 °C: 355.1697687 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.567865017 V-1     T = -25 °C: 4.718495669 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.009745428 V-1     T = -25 °C: 9.521302907 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.92150217 V-1     T = -25 °C: 15.03826862 V-1
Break-through voltage: T = +20 °C: 406.9323862 V     T = -25 °C: 370.4241576 V
   
Notes: Wrong wafer number in serial number, correct wafer number is 3.


Version history

Time Author Change comment
26. Oct 2021 10:30:13 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:58 CEST jreher Updated box and position via API.
05. Feb 2021 11:26:19 CET jreher Updated box and position via API.
11. Aug 2020 17:56:17 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:41:42 CEST jreher Updated APD location via API.
21. Jul 2020 14:41:32 CEST jreher Updated box and position via API.
19. Dec 2019 15:45:13 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:17:11 CET jreher Updated box and position via API.
17. Nov 2017 09:39:16 CET markus.moritz Entered shipped after irradiation date.
17. Nov 2017 09:38:13 CET markus.moritz Entered irradiation information.
09. Nov 2017 15:11:05 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:53 CET Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:03:46 CEST Tobias Added note about wrong wafer number.
22. Jun 2016 15:31:42 CEST Tobias Imported from Hamamatsu datasheet.