Show Hamamatsu Avalanche Photo Diode 0902009165 - Archived data from Wed, 22. June 2016 15:31:41 CEST
This is all the information about APD 0902009165. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0902009165 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E14 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.5 V |
Dark current: | 7.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 294 |
Position in Box: | 43 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
15. Apr 2021 15:53:22 CEST | oafedulidis | Assigned to capsule by script |
16. Feb 2021 12:27:37 CET | jreher | Updated box and position via API. |
05. Feb 2021 11:26:15 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:15 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:29 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:41:20 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:44:46 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:06 CET | jreher | Updated box and position via API. |
17. Nov 2017 09:39:16 CET | markus.moritz | Entered shipped after irradiation date. |
17. Nov 2017 09:38:13 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:11:05 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:53 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:03:46 CEST | Tobias | Added note about wrong wafer number. |
22. Jun 2016 15:31:41 CEST | Tobias | Imported from Hamamatsu datasheet. |