RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0901009034 - Archived data from Wed, 07. October 2020 12:18:07 CEST


This is all the information about APD 0901009034. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0901009034
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2318025643/0901009034
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.4 V
Dark current: 5.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 57
Position in Box: 25
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.2177959 V     T = -25 °C: 349.5890501 V
Voltage for Gain 150: T = +20 °C: 393.167954 V     T = -25 °C: 357.0912811 V
Voltage for Gain 200: T = +20 °C: 397.5548497 V     T = -25 °C: 361.283959 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.496143642 V-1     T = -25 °C: 4.685908376 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.398750066 V-1     T = -25 °C: 9.248893736 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.86962385 V-1     T = -25 °C: 14.17886873 V-1
Break-through voltage: T = +20 °C: 413.1023264 V     T = -25 °C: 376.694967 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:43 CET jreher Updated box and position via API.
03. Feb 2021 18:21:16 CET jreher Updated box and position via API.
07. Oct 2020 12:18:07 CEST jreher Assigned to capsule by script
06. Oct 2020 16:51:24 CEST jreher Updated box and position via API.
11. Aug 2020 17:28:19 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:38:49 CET jreher Updated APD location via API.
25. Nov 2019 17:15:24 CET jreher Updated box and position via API.
04. Jul 2019 11:12:58 CEST jreher Updated APD location via API.
03. Jul 2019 18:43:28 CEST jreher Updated APD batch assignment via API.
24. Jun 2019 13:02:36 CEST jgrochowski Updated APD batch assignment via API.
18. Jun 2019 14:19:32 CEST jgrochowski Updated APD batch assignment via API.
04. Jun 2019 13:35:43 CEST markus.moritz
22. Jun 2016 15:31:38 CEST Tobias Imported from Hamamatsu datasheet.