RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0821008806 - Archived data from Fri, 16. April 2021 22:01:12 CEST


This is all the information about APD 0821008806. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0821008806
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E01
Break-through voltage: 401 V
Voltage for Gain 100 (T=+25°C): 374.5 V
Dark current: 2.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 357
Position in Box: 45
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.8920266 V     T = -25 °C: 340.8982587 V
Voltage for Gain 150: T = +20 °C: 383.7097023 V     T = -25 °C: 348.0994333 V
Voltage for Gain 200: T = +20 °C: 388.0426555 V     T = -25 °C: 352.1382271 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.669134175 V-1     T = -25 °C: 5.106369888 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.27403723 V-1     T = -25 °C: 9.607496153 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.57918713 V-1     T = -25 °C: 15.38921094 V-1
Break-through voltage: T = +20 °C: 398.5641283 V     T = -25 °C: 365.4869407 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 14:45:24 CEST oafedulidis Updated box and position via API.
16. Apr 2021 22:01:12 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:34:08 CET jreher Updated box and position via API.
08. Oct 2020 18:15:37 CEST jreher Updated APD location via API.
17. Aug 2020 14:33:54 CEST vwerner Updated APD batch assignment via API.
22. Jun 2016 15:29:40 CEST Tobias Imported from Hamamatsu datasheet.