Serial: 0820008778
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0820008778/2308024781
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 382.1 V
Dark current: 3.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 190
Position in Box: 33
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.828396 V     T = -25 °C: 346.0715212 V
Voltage for Gain 150: T = +20 °C: 389.7769503 V     T = -25 °C: 353.5157237 V
Voltage for Gain 200: T = +20 °C: 394.1937745 V     T = -25 °C: 357.6796099 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.59023109 V-1     T = -25 °C: 4.937125683 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.078373637 V-1     T = -25 °C: 8.93846858 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.03387509 V-1     T = -25 °C: 15.75437895 V-1
Break-through voltage: T = +20 °C: 409.7760396 V     T = -25 °C: 373.2871782 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 13:59:48 CEST jreher Updated box and position via API.
05. Feb 2021 11:12:53 CET jreher Updated box and position via API.
07. Oct 2020 14:22:34 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:53 CEST jreher Updated box and position via API.
11. Aug 2020 17:34:53 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:02:41 CET jreher Updated APD location via API.
25. Nov 2019 17:25:51 CET jreher Updated box and position via API.
16. Aug 2019 10:43:33 CEST spankonin Updated APD batch assignment via API.
13. Aug 2019 12:17:29 CEST jreher Updated APD location via API.
09. Aug 2019 17:00:10 CEST spankonin Updated APD batch assignment via API.
07. Aug 2019 13:34:01 CEST markus.moritz
22. Jun 2016 15:29:39 CEST Tobias Imported from Hamamatsu datasheet.