Show Hamamatsu Avalanche Photo Diode 0820008732 - Archived data from Fri, 16. April 2021 22:00:43 CEST
This is all the information about APD 0820008732. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0820008732 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D08 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.4 V |
Dark current: | 3.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 353 |
Position in Box: | 10 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 382.0364012 V T = -25 °C: 346.7925477 V |
Voltage for Gain 150: | T = +20 °C: 389.8946809 V T = -25 °C: 354.2252696 V |
Voltage for Gain 200: | T = +20 °C: 394.2639919 V T = -25 °C: 358.4387734 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.596191711 V-1 T = -25 °C: 4.998492979 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.089728005 V-1 T = -25 °C: 9.207981321 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.21645446 V-1 T = -25 °C: 14.31219065 V-1 |
Break-through voltage: | T = +20 °C: 410.9982891 V T = -25 °C: 373.8794264 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
21. Apr 2021 14:47:12 CEST | oafedulidis | Updated box and position via API. |
16. Apr 2021 22:00:43 CEST | jreher | Updated APD characteristics via API. |
05. Feb 2021 11:33:33 CET | jreher | Updated box and position via API. |
08. Oct 2020 18:14:48 CEST | jreher | Updated APD location via API. |
17. Aug 2020 14:22:08 CEST | vwerner | Updated APD batch assignment via API. |
22. Jun 2016 15:29:38 CEST | Tobias | Imported from Hamamatsu datasheet. |