Show Hamamatsu Avalanche Photo Diode 0818008573 - Archived data from Tue, 22. October 2019 14:32:01 CEST
This is all the information about APD 0818008573. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0818008573 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 290 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G03 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 384.6 V |
Dark current: | 2.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 290 |
Position in Box: | 43 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 67 |
Position in grid: | 5 |
Arrival for irradiation: | 15. May 2016 |
Sent for analysis after irradiation: | 23. Jun 2016 |
Return for assembly: | 29. Nov 2016 |
Irradiation: | |
Date: | 20. May 2016 |
Dose used: | 250 Gy |
Temperature: | -25 °C |
Position: | 1 |
Bias voltage: | 320 V (connection unknown) |
Annealing: | |
Date: | 20. May 2016 |
Temperature: | 80 °C |
Duration: | 8 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:45 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:40:26 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:42 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:51 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:30 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:32:01 CEST | spankonin | Updated APD location via API. |
15. Oct 2019 11:02:54 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Nov 2016 11:51:58 CET | markus.moritz | Entered return for assembly date. |
04. Aug 2016 12:45:56 CEST | markus.moritz | Entered arrival for irradiation date. |
03. Aug 2016 16:03:20 CEST | markus.moritz | Entered shipped after irradiation date. |
03. Aug 2016 16:03:08 CEST | markus.moritz | Entered arrival for irradiation date. |
02. Aug 2016 15:18:06 CEST | christopher.l.hahn | Entered annealing information. |
02. Aug 2016 14:00:56 CEST | markus.moritz | Entered irradiation information. |
01. Aug 2016 17:27:50 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:27:54 CEST | Tobias | Imported from Hamamatsu datasheet. |