Show Hamamatsu Avalanche Photo Diode 0816008466 - Archived data from Tue, 11. August 2020 17:56:50 CEST
This is all the information about APD 0816008466. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0816008466 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D15 |
Break-through voltage: | 409 V |
Voltage for Gain 100 (T=+25°C): | 383.7 V |
Dark current: | 5.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 298 |
Position in Box: | 20 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 65 |
Position in grid: | 14 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 17. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Aug 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 383.7 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 383.1088325 V T = -25 °C: 347.6996396 V |
Voltage for Gain 150: | T = +20 °C: 391.0958998 V T = -25 °C: 355.130338 V |
Voltage for Gain 200: | T = +20 °C: 395.5255078 V T = -25 °C: 359.3051386 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.470231635 V-1 T = -25 °C: 5.015947547 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.710249226 V-1 T = -25 °C: 9.28823432 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.15733651 V-1 T = -25 °C: 14.43803071 V-1 |
Break-through voltage: | T = +20 °C: 408.2405088 V T = -25 °C: 372.3029399 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:26:44 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:50 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:42:26 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:42:16 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:49:37 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:36 CET | jreher | Updated box and position via API. |
23. Aug 2017 16:06:04 CEST | markus.moritz | Entered shipped after irradiation date. |
09. Aug 2017 14:26:11 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 16:54:16 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
07. Aug 2017 16:46:04 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
04. Aug 2017 03:15:07 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:27:52 CEST | Tobias | Imported from Hamamatsu datasheet. |