Show Hamamatsu Avalanche Photo Diode 0816008449 - Archived data from Tue, 11. August 2020 17:56:48 CEST
This is all the information about APD 0816008449. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0816008449 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F09 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 385.4 V |
Dark current: | 4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 298 |
Position in Box: | 9 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 65 |
Position in grid: | 3 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 17. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Aug 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 385.4 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 385.2923445 V T = -25 °C: 349.4662973 V |
Voltage for Gain 150: | T = +20 °C: 393.2478406 V T = -25 °C: 356.9389845 V |
Voltage for Gain 200: | T = +20 °C: 397.6747855 V T = -25 °C: 361.1336008 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.443727399 V-1 T = -25 °C: 4.704296719 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.684801591 V-1 T = -25 °C: 9.599992339 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.0027021 V-1 T = -25 °C: 14.89008313 V-1 |
Break-through voltage: | T = +20 °C: 412.701619 V T = -25 °C: 376.3067405 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:26:43 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:48 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:42:25 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:42:16 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:49:36 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:35 CET | jreher | Updated box and position via API. |
23. Aug 2017 16:06:04 CEST | markus.moritz | Entered shipped after irradiation date. |
09. Aug 2017 14:26:10 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 16:54:16 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
07. Aug 2017 16:46:04 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
04. Aug 2017 03:15:05 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:27:52 CEST | Tobias | Imported from Hamamatsu datasheet. |