RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0812008143 - Archived data from Fri, 05. February 2021 11:13:09 CET


This is all the information about APD 0812008143. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0812008143
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H09
Break-through voltage: 418 V
Voltage for Gain 100 (T=+25°C): 389 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 192
Position in Box: 35
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.7217864 V     T = -25 °C: 353.2630237 V
Voltage for Gain 150: T = +20 °C: 397.57722 V     T = -25 °C: 360.8245462 V
Voltage for Gain 200: T = +20 °C: 401.9241841 V     T = -25 °C: 365.0814553 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.671664926 V-1     T = -25 °C: 4.70002137 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.254341858 V-1     T = -25 °C: 9.326613264 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.41253557 V-1     T = -25 °C: 14.4427727 V-1
Break-through voltage: T = +20 °C: 417.9901075 V     T = -25 °C: 380.7633889 V
   
Notes:


Version history

Time Author Change comment
11. Jul 2022 14:23:48 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:29:51 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:13:09 CET jreher Updated box and position via API.
11. Aug 2020 17:35:13 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:03:03 CET jreher Updated APD location via API.
25. Nov 2019 17:26:01 CET jreher Updated box and position via API.
16. Aug 2019 12:20:37 CEST jreher Updated APD location via API.
09. Aug 2019 16:25:32 CEST jreher Updated APD batch assignment via API.
07. Aug 2019 15:03:03 CEST markus.moritz
22. Jun 2016 15:26:18 CEST Tobias Imported from Hamamatsu datasheet.