Show Hamamatsu Avalanche Photo Diode 0812008127 - Archived data from Tue, 11. August 2020 17:56:10 CEST
This is all the information about APD 0812008127. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0812008127 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | H11 |
Break-through voltage: | 416 V |
Voltage for Gain 100 (T=+25°C): | 390.2 V |
Dark current: | 3.1 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 294 |
Position in Box: | 19 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 110 |
Position in grid: | 10 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 23. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 10. Aug 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 390.2 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.1535382 V T = -25 °C: 354.925933 V |
Voltage for Gain 150: | T = +20 °C: 399.044151 V T = -25 °C: 362.5704217 V |
Voltage for Gain 200: | T = +20 °C: 403.4263632 V T = -25 °C: 366.8374205 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.509411655 V-1 T = -25 °C: 4.760743063 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.849793776 V-1 T = -25 °C: 9.561347234 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.4750121 V-1 T = -25 °C: 14.89749745 V-1 |
Break-through voltage: | T = +20 °C: 414.9067311 V T = -25 °C: 380.0451891 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:26:12 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:10 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:28 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:41:18 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:43:53 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:04 CET | jreher | Updated box and position via API. |
23. Aug 2017 15:55:25 CEST | markus.moritz | Entered shipped after irradiation date. |
10. Aug 2017 16:44:22 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 18:17:15 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
07. Aug 2017 17:47:02 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:26:17 CEST | Tobias | Imported from Hamamatsu datasheet. |