Show Hamamatsu Avalanche Photo Diode 0812008125 - Archived data from Thu, 16. December 2021 13:42:35 CET
This is all the information about APD 0812008125. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0812008125 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F12 |
Break-through voltage: | 419 V |
Voltage for Gain 100 (T=+25°C): | 390.9 V |
Dark current: | 4.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 294 |
Position in Box: | 17 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 110 |
Position in grid: | 6 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 23. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 10. Aug 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 390.9 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.0478134 V T = -25 °C: 354.8405637 V |
Voltage for Gain 150: | T = +20 °C: 398.8978869 V T = -25 °C: 362.4288035 V |
Voltage for Gain 200: | T = +20 °C: 403.2588505 V T = -25 °C: 366.6729241 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.578784219 V-1 T = -25 °C: 4.829981694 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.063605491 V-1 T = -25 °C: 8.856147343 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.10389227 V-1 T = -25 °C: 15.46203448 V-1 |
Break-through voltage: | T = +20 °C: 418.1376979 V T = -25 °C: 381.9726014 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2022 09:59:03 CET | oafedulidis | Assigned to capsule by script |
16. Dec 2021 13:42:35 CET | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:26:12 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:10 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:27 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:41:18 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:43:53 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:04 CET | jreher | Updated box and position via API. |
23. Aug 2017 15:55:25 CEST | markus.moritz | Entered shipped after irradiation date. |
10. Aug 2017 16:44:22 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 18:17:15 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
07. Aug 2017 17:47:02 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:26:17 CEST | Tobias | Imported from Hamamatsu datasheet. |