Show Hamamatsu Avalanche Photo Diode 0812008113 - Archived data from Thu, 19. December 2019 15:17:03 CET
This is all the information about APD 0812008113. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0812008113 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C03 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.5 V |
Dark current: | 3.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 294 |
Position in Box: | 9 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 109 |
Position in grid: | 5 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 17. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 10. Aug 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 381.5 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
15. Apr 2021 15:53:26 CEST | oafedulidis | Assigned to capsule by script |
16. Feb 2021 12:27:36 CET | jreher | Updated box and position via API. |
05. Feb 2021 11:26:11 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:09 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:27 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:41:17 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:43:52 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:03 CET | jreher | Updated box and position via API. |
23. Aug 2017 16:05:34 CEST | markus.moritz | Entered shipped after irradiation date. |
10. Aug 2017 15:10:29 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 17:01:31 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
04. Aug 2017 03:15:31 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:26:17 CEST | Tobias | Imported from Hamamatsu datasheet. |