RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0812008080 - Archived data from Tue, 11. August 2020 17:35:49 CEST


This is all the information about APD 0812008080. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0812008080
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2516028815/0812008080
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: B06
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.9 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 196
Position in Box: 17
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.5395637 V     T = -25 °C: 346.8953367 V
Voltage for Gain 150: T = +20 °C: 390.392302 V     T = -25 °C: 354.2696605 V
Voltage for Gain 200: T = +20 °C: 394.7447624 V     T = -25 °C: 358.419451 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.38112307 V-1     T = -25 °C: 4.936639006 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.351801835 V-1     T = -25 °C: 9.065895622 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.54817226 V-1     T = -25 °C: 15.98203953 V-1
Break-through voltage: T = +20 °C: 409.7126803 V     T = -25 °C: 373.4154006 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:13:39 CET jreher Updated box and position via API.
11. Aug 2020 17:35:49 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:53:12 CEST jreher Assigned to capsule by script
13. Feb 2020 14:22:29 CET jreher Updated box and position via API.
13. Feb 2020 14:22:17 CET jreher Updated box and position via API.
27. Nov 2019 20:03:45 CET jreher Updated APD location via API.
25. Nov 2019 17:26:18 CET jreher Updated box and position via API.
16. Aug 2019 12:21:19 CEST jreher Updated APD location via API.
09. Aug 2019 17:04:55 CEST spankonin Updated APD batch assignment via API.
31. Jul 2019 14:57:00 CEST markus.moritz
22. Jun 2016 15:26:16 CEST Tobias Imported from Hamamatsu datasheet.