Show Hamamatsu Avalanche Photo Diode 0810007947 - Archived data from Tue, 11. August 2020 17:56:27 CEST
This is all the information about APD 0810007947. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0810007947 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G11 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 389.6 V |
Dark current: | 3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 296 |
Position in Box: | 2 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 102 |
Position in grid: | 2 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 23. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 10. Aug 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 389.6 V (connection unknown) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.7850225 V T = -25 °C: 353.5067378 V |
Voltage for Gain 150: | T = +20 °C: 397.6480538 V T = -25 °C: 361.0541995 V |
Voltage for Gain 200: | T = +20 °C: 402.0018248 V T = -25 °C: 365.2971699 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.652917192 V-1 T = -25 °C: 4.615213345 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.259227665 V-1 T = -25 °C: 9.188429216 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.45151276 V-1 T = -25 °C: 14.35420476 V-1 |
Break-through voltage: | T = +20 °C: 417.1559128 V T = -25 °C: 381.021465 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
21. Apr 2021 14:48:03 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:26:26 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:27 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:55 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:41:46 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:46:11 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:19 CET | jreher | Updated box and position via API. |
23. Aug 2017 15:54:49 CEST | markus.moritz | Entered shipped after irradiation date. |
10. Aug 2017 16:42:43 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 17:00:42 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
04. Aug 2017 03:15:27 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:26:13 CEST | Tobias | Imported from Hamamatsu datasheet. |