RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0809007919 - Archived data from Wed, 22. June 2016 15:26:13 CEST


This is all the information about APD 0809007919. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0809007919
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 393.2 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 186
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:16:48 CET oafedulidis Assigned to capsule by script
16. Dec 2021 13:41:14 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:12:22 CET jreher Updated box and position via API.
11. Aug 2020 17:33:56 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:01:57 CET jreher Updated APD location via API.
25. Nov 2019 17:25:34 CET jreher Updated box and position via API.
13. Aug 2019 12:10:45 CEST spankonin Updated APD location via API.
07. Aug 2019 14:15:03 CEST markus.moritz
05. Aug 2019 17:05:53 CEST jreher Updated APD batch assignment via API.
22. Jun 2016 15:26:13 CEST Tobias Imported from Hamamatsu datasheet.