RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0809007908


This is all the information about APD 0809007908. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0809007908
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H09
Break-through voltage: 424 V
Voltage for Gain 100 (T=+25°C): 396.9 V
Dark current: 3.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 186
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: 10140
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 397.485653 V     T = -25 °C: 360.898197 V
Voltage for Gain 150: T = +20 °C: 405.3700639 V     T = -25 °C: 368.6391605 V
Voltage for Gain 200: T = +20 °C: 409.7347752 V     T = -25 °C: 372.9497278 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.391129904 V-1     T = -25 °C: 4.724491646 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.592525638 V-1     T = -25 °C: 9.372876966 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.84161393 V-1     T = -25 °C: 14.61610653 V-1
Break-through voltage: T = +20 °C: 424.8777043 V     T = -25 °C: 388.4246078 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
05. Feb 2021 11:12:21 CET jreher Updated box and position via API.
11. Aug 2020 17:33:53 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:01:57 CET jreher Updated APD location via API.
25. Nov 2019 17:25:33 CET jreher Updated box and position via API.
13. Aug 2019 12:16:55 CEST jreher Updated APD location via API.
07. Aug 2019 14:11:02 CEST markus.moritz
05. Aug 2019 17:05:52 CEST jreher Updated APD batch assignment via API.
22. Jun 2016 15:26:12 CEST Tobias Imported from Hamamatsu datasheet.