RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0616005241 - Archived data from Tue, 11. August 2020 17:47:44 CEST


This is all the information about APD 0616005241. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0616005241
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G03
Break-through voltage: 436 V
Voltage for Gain 100 (T=+25°C): 408.4 V
Dark current: 13.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 240
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 409.4385903 V     T = -25 °C: 372.3636345 V
Voltage for Gain 150: T = +20 °C: 417.3781867 V     T = -25 °C: 380.204375 V
Voltage for Gain 200: T = +20 °C: 421.7568718 V     T = -25 °C: 384.5601318 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.409264525 V-1     T = -25 °C: 4.478213839 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.617280494 V-1     T = -25 °C: 8.829515422 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.00315545 V-1     T = -25 °C: 15.53664808 V-1
Break-through voltage: T = +20 °C: 435.8059016 V     T = -25 °C: 399.1641176 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:19:16 CET jreher Updated box and position via API.
11. Aug 2020 17:47:44 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:31:01 CEST jreher Updated box and position via API.
27. Nov 2019 20:11:35 CET jreher Updated APD location via API.
25. Nov 2019 17:29:33 CET jreher Updated box and position via API.
18. Nov 2019 18:21:21 CET spankonin Updated APD location via API.
18. Nov 2019 18:05:27 CET spankonin Updated APD batch assignment via API.
18. Jun 2019 10:18:38 CEST Tobias Imported from Hamamatsu datasheet.