RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0616005239 - Archived data from Tue, 11. August 2020 18:09:01 CEST


This is all the information about APD 0616005239. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0616005239
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G09
Break-through voltage: 445 V
Voltage for Gain 100 (T=+25°C): 417.5 V
Dark current: 14.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 267
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 437.1368441 V     T = -25 °C: 376.4630429 V
Voltage for Gain 150: T = +20 °C: 438.5998095 V     T = -25 °C: 378.5488319 V
Voltage for Gain 200: T = +20 °C: 438.5998095 V     T = -25 °C: 378.7684894 V
Gain/Voltage slope at M = 100: T = +20 °C: 13.23026954 V-1     T = -25 °C: 62.04626874 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 16.35943214 V-1     T = -25 °C: 227.627115 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 16.35943214 V-1     T = -25 °C: 227.627115 V-1
Break-through voltage: T = +20 °C: 438.884221 V     T = -25 °C: 407.7766843 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:14 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:34:44 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:34:29 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:22:45 CET jreher Updated box and position via API.
07. Oct 2020 15:44:35 CEST jreher Updated APD location via API.
11. Aug 2020 18:09:01 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:44 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:34 CEST jreher Updated box and position via API.
29. Jun 2020 16:10:16 CEST jreher Updated APD batch assignment via API.
18. Jun 2019 10:18:38 CEST Tobias Imported from Hamamatsu datasheet.