RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0616005232 - Archived data from Wed, 10. November 2021 14:34:30 CET


This is all the information about APD 0616005232. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0616005232
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F14
Break-through voltage: 450 V
Voltage for Gain 100 (T=+25°C): 421.9 V
Dark current: 14.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 267
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 439.1436385 V     T = -25 °C: 376.8369371 V
Voltage for Gain 150: T = +20 °C: 439.1436385 V     T = -25 °C: 388.8928665 V
Voltage for Gain 200: T = +20 °C: 439.1436385 V     T = -25 °C: 392.6090468 V
Gain/Voltage slope at M = 100: T = +20 °C: 6.517638001 V-1     T = -25 °C: 85.24900973 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 6.517638001 V-1     T = -25 °C: 55.77330407 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 6.517638001 V-1     T = -25 °C: 170.1454354 V-1
Break-through voltage: T = +20 °C: 439.3326865 V     T = -25 °C: 414.3605555 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:15 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:34:45 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:34:30 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:22:46 CET jreher Updated box and position via API.
07. Oct 2020 15:44:36 CEST jreher Updated APD location via API.
11. Aug 2020 18:09:03 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:45 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:35 CEST jreher Updated box and position via API.
29. Jun 2020 16:10:17 CEST jreher Updated APD batch assignment via API.
18. Jun 2019 10:18:38 CEST Tobias Imported from Hamamatsu datasheet.