RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0809007871 - Archived data from Tue, 11. August 2020 17:33:49 CEST


This is all the information about APD 0809007871. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0809007871
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E14
Break-through voltage: 423 V
Voltage for Gain 100 (T=+25°C): 394.9 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 186
Position in Box: 11
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.922206 V     T = -25 °C: 358.3861997 V
Voltage for Gain 150: T = +20 °C: 402.7687029 V     T = -25 °C: 366.0440936 V
Voltage for Gain 200: T = +20 °C: 407.1110713 V     T = -25 °C: 370.3304642 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.606523614 V-1     T = -25 °C: 4.613543731 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.210583867 V-1     T = -25 °C: 9.126864148 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.39968088 V-1     T = -25 °C: 14.16339173 V-1
Break-through voltage: T = +20 °C: 422.2011384 V     T = -25 °C: 385.8009215 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:12:18 CET jreher Updated box and position via API.
11. Aug 2020 17:33:49 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:01:55 CET jreher Updated APD location via API.
25. Nov 2019 17:25:31 CET jreher Updated box and position via API.
13. Aug 2019 12:16:53 CEST jreher Updated APD location via API.
07. Aug 2019 14:04:46 CEST markus.moritz
05. Aug 2019 17:06:07 CEST jreher Updated APD batch assignment via API.
22. Jun 2016 15:26:11 CEST Tobias Imported from Hamamatsu datasheet.